BidKar
3 days leftOpen to foreign firmsGoods supply

Graphite Furnace Atomic Absorption Spectrometer

Country
Buyer
COMMERCE, DEPARTMENT OF / NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY
Closing
29 Nov 2026, 00:00 (Pakistan time)
Published
28 Oct 2026
Type of notice
Sources Sought
Category
Goods · NAICS 334516
Reference
NIST-MML-FY27-SS01
Place of performance
Gaithersburg, MD
NAICS code
334516
Source
Who can bid

Not set aside: foreign firms may bid, but US trade rules (Buy American / Trade Agreements Act) can limit goods made in Pakistan - read the clauses first.

Summary from the notice

Sources Sought Notice for Graphite Furnace Atomic Absorption Spectrometer Notice ID: NIST-MML-FY27-SS01 Response Date: 11/28/2026 Product Service Code (PSC): 6640 NAICS Code: 334516 Background The Inorganic Chemical Metrology Group (ICMG) uses at least two measurement methods, each based on orthogonal physical principles, to certify the trace elements in candidate standard reference materials (SRM). These SRMs are intended for method validation and quality assurance in trace-element measurements to assess the nutritional value and contaminant status of agricultural products. A sensitive trace-element detector, a graphite furnace atomic absorption spectrometer (GFAAS) is sought to complement the group's inductively coupled plasma mass spectrometric (ICP-MS) measurement capability and fulfill the two independent method requirements for SRM development. Consideration will be given to GFAAS capable of direct solid-sample analysis to maximize its orthogonality relative to the liquid-sampling-based ICP-MS technique. Minimum Capabilities that NIST Requires and for Which Information is Being Requested The National Institute for Standards and Technology (NIST) located in Gaithersburg, MD is seeking information on vendors that are capable of providing a graphite furnace atomic absorption spectrometer (1) capable of measuring liquid test samples with an instrument detection limit (DL) for Cu at 0.02 �g/L or better (324.8 nm line, 50 �L sample volume, DL=3 x standard deviation of 10 replications) and (2) designed for direct introduction of solid state test samples into the graphite furnace for analyte quantification without a need of sample digestion Instructions for Responding to This Notice Parties that respond to this Notice are requested to submit the requested information…

Open the original notice on SAM.gov

BidKar lists this notice to help you find it. Bids go to the buyer through the portal named above, never through BidKar. Check the original documents for the latest dates and conditions.